Knowledge

Standard Testing Technique Requirements for FIBC in the world markets

BS6382 & AS3668--1989

Stacking Testing

The Load of 4xSWL was loaded to a flat plate placed on the top of Filled FIBC and maintained for 24 Hours.


Cyclic Top lift Test 

1. For Single Trip Use

2xSWL(including the contents) was loaded to a flat plate placed on the top of the contents and then remove the applied load; Repeat the test procedure mentioned above for 30 cycles; Carry out a further test cyclic at the test load of 5xSWL(including the contents)

 

2. For Multi-trip Use    

 4xSWL(including the contents) was loaded to a flat plate placed on the top of the contents and then remove the applied load; Repeat the test procedure mentioned above for 70 cycles; Carry out a further test cyclic at the test load of 6xSWL(including the contents) 



EN ISO21898-2005

Stacking Testing

The Load of 4xSWL was loaded to a flat plate placed on the top of Filled FIBC and maintained for 6 Hours.


Cyclic Top lift Test 

1. For Single Trip Use

2xSWL(including the contents) was loaded to a flat plate placed on the top of the contents and then remove the applied load; Repeat the test procedure mentioned above for 30 cycles; Carry out a further test cyclic at the test load of 5xSWL(including the contents)

 

2. For Standard-Duty Reusable

4xSWL(including the contents) was loaded to a flat plate placed on the top of the contents and then remove the applied load; Repeat the test procedure mentioned above for 70 cycles; Carry out a further test cyclic at the test load of 6xSWL(including the contents)

 

3. For Heavy-Duty Reusable

6xSWL(including the contents) was loaded to a flat plate placed on the top of the contents and then remove the applied load; Repeat the test procedure mentioned above for 70 cycles; Carry out a further test cyclic at the test load of 8xSWL(including the contents)



EFIBCA

Stacking Testing

The Load of 4xSWL was loaded to a flat plate placed on the top of Filled FIBC and maintained for more than 30 seconds.


Cyclic Top lift Test

1. For Single Trip Use

2xSWL(including the contents) was loaded to a flat plate placed on the top of the contents and then remove the applied load; Repeat the test procedure mentioned above for 30 cycles; Carry out a further test cyclic at the test load of 5xSWL(including the contents)

 

 

2. For Standard-Duty Reusable

4xSWL(including the contents) was loaded to a flat plate placed on the top of the contents and then remove the applied load; Repeat the test procedure mentioned above for 70 cycles; Carry out a further test cyclic at the test load of 6xSWL(including the contents)

 

 

3. For Heavy-Duty Reusable

6xSWL(including the contents) was loaded to a flat plate placed on the top of the contents and then remove the applied load; Repeat the test procedure mentioned above for 70 cycles; Carry out a further test cyclic at the test load of 8xSWL(including the contents)




You Might Also Like